Storage-EMC - Data Domain - DDOS v5.4.0.8
Description
Applicable on the data domain storage devices. Monitors the disk, filesystem, power module status, temperature status, system statistics etc.. Data Domain OS 5.4.0.8-404909. SNMP Obj Id=1.3.6.1.4.1.19746.3.1.36. . Open TCP ports[139,443,80,22,]
Prerequisites
No prerequisite
Supported Metric
| Monitor Name | Metric Name | Metric Display Name | Unit | Description |
|---|---|---|---|---|
| DD Disk Status - DDOS V5.4.0.8 | dd.system.disk.errstatus | DD Disk Status - DDOS V5.4.0.8 | Provides the current state of the disk. Possible status values are 1- Ok, 2- Unknown, 3- Absent, 4- Failed, 5- Spare, 6- Available. [OID: 1.3.6.1.4.1.19746.1.6.3.1.1.3, 1.3.6.1.4.1.19746.1.6.3.1.1.14] | |
| DD FAN Sensor Status - DDOS V5.4.0.8 | dd.fan.sensor.status | DD FAN Sensor Status - DDOS V5.4.0.8 | Provides the current status of the fan. Possible status values are 0 - Not Found, 1 - Ok, 2 - Failed. [OID: 1.3.6.1.4.1.19746.1.1.3.1.1.1.4, 1.3.6.1.4.1.19746.1.1.3.1.1.1.6] | |
| DD File System Space Used - DDOS V5.4.0.8 | dd.filesystem.utilization | DD File System Space Used - DDOS V5.4.0.8 | % | Provides the percentage of used space within the file system resource. [OID: 1.3.6.1.4.1.19746.1.3.2.1.1.3, 1.3.6.1.4.1.19746.1.3.2.1.1.7] |
| DD File System Status - DDOS V5.4.0.8 | dd.filesystem.status | DD File System Status - DDOS V5.4.0.8 | Provides the status of the data domain file system. Possible status values are 1- Enabled, 2- Disabled, 3- Running, 4- Unknown, 5- Error, 6- Cleaning. [OID: 1.3.6.1.4.1.19746.1.3.1.1.0] | |
| DD NVRAM Battery Status - DDOS V5.4.0.8 | dd.nvram.battery.status | DD NVRAM Battery Status - DDOS V5.4.0.8 | Provides the NVRAM battery status of the data domain. Possible status values are 0- Ok, 1- Disabled, 2- Discharged, 3- Unknown, 4- Softdisabled. [OID: 1.3.6.1.4.1.19746.1.2.3.1.1.2,\n1.3.6.1.4.1.19746.1.2.3.1.1.3] | |
| DD Power Module Status - DDOS V5.4.0.8 | dd.power.module.status | DD Power Module Status - DDOS V5.4.0.8 | Provides the power module status of data domain. Possible status values are 0- Absent, 1 - Ok, 2- Failed, 3- Faulty, 4- Acnone, 99- Unknown. [OID: 1.3.6.1.4.1.19746.1.1.1.1.1.1.2,\n1.3.6.1.4.1.19746.1.1.1.1.1.1.4] | |
| DD Replication Status - DDOS V5.4.0.8 | dd.replicationstate.advanced2 | DD Replication State - DDOS V5.4.0.8 | Provides the state of the replication source/dest pair connection. Possible status values for state are: 1- Initializing, 2- Normal, 3- Recovering, 4- Uninitialized. | |
| dd.replicationstatus.advanced2 | DD Replication Status - DDOS V5.4.0.8 | Provides the status of the replication source/dest pair connection. Possible status values for status are: 1- Connected, 2- Disconnected, 3- Migrating, 4- Suspended, 5- NeverConnected, 6- Idle.[OID: 1.3.6.1.4.1.19746.1.8.1.1.1.1, 1.3.6.1.4.1.19746.1.8.1.1.1.4]\n | ||
| DD System Statistics - DDOS V5.4.0.8 | dd.system.cpu.max | DD System CPU Max - DDOS V5.4.0.8 | % | CPU Max Percentage Busy. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.3] |
| dd.system.cpu.avg | DD System CPU Average - DDOS V5.4.0.8 | % | CPU Average Percentage Busy. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.2] | |
| dd.disk.busy.percent | DD Disk Busy Percent - DDOS V5.4.0.8 | % | Percentage of Time Disks were busy. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.12] | |
| dd.nfs.oper.persec | NFS Operations - DDOS V5.4.0.8 | psec | Number of NFS Operations performed per second. [OID: 1.3.6.1.4.1.19746.1.5.1.1.1.4] | |
| DD Temperature Sensor Status - DDOS V5.4.0.8 | dd.temp.sensor.currentvalue | DD Temperature Sensor Value - DDOS V5.4.0.8 | C | Current Temperature Value of the sensor. [OID: 1.3.6.1.4.1.19746.1.1.2.1.1.1.5] |
| dd.temp.sensor.status | DD Temperature Sensor Status - DDOS V5.4.0.8 | Provides the status the temperature sensor. Possible status values are 0- Failed, 1- Ok, 2- Notfound, 3- OverheatWarning, 4- OverheatCritical. [OID: 1.3.6.1.4.1.19746.1.1.2.1.1.1.4,\n1.3.6.1.4.1.19746.1.1.2.1.1.1.6] |