Juniper SRX IDP Attack
Description
Monitors the number of times an attack has been identified by the Intrusion Detection and Prevention (IDP) system. The metrics are as follows:
- Attack Name: Tracks the name of the attack identified by the IDP.
- Attack Hits: Monitors the number of times the attack has occurred.
These metrics are gathered via the following SNMP OIDs:
- IDP Attack Name:
1.3.6.1.4.1.2636.3.39.1.11.1.1.7.1.2
- IDP Attack Hits:
1.3.6.1.4.1.2636.3.39.1.11.1.1.7.1.3
Prerequisites
None
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper SRX IDP Attack | juniper_srx_idp_AttackHits | Juniper SRX IDP Attack Hits | It monitors number of times an attack has been hit and this is a rate-based metric that provides the number of Juniper SRX IDP attack hits per second.(JUNIPER-JS-IDP-MIB :: jnxJsIdpAttackHits : 1.3.6.1.4.1.2636.3.39.1.11.1.1.7.1.3) |
Juniper VPN IPsec Tunnel Status
Description
Monitors the status of Juniper VPN IPSEC Tunnel. [ JUNIPER-IPSEC-FLOW-MON-MIB :: jnxIpSecSaMonState : 1.3.6.1.4.1.2636.3.52.1.2.3.1.14 ]
Prerequisites
Device must have support for JUNIPER-IPSEC-FLOW-MON-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper VPN IPsec Tunnel Status | juniper_vpn_IpsecTunnelStatus | Juniper VPN IPsec Tunnel Status | Monitors the Juniper VPN IPsec Tunnel SA Status. [ JUNIPER-IPSEC-FLOW-MON-MIB :: jnxIpSecSaMonState : 1.3.6.1.4.1.2636.3.52.1.2.3.1.14 ] Possible values are : 1 : up , 2 : down. |
Juniper - CPU Utilization Last 1 & 15 Minutes
Description
Applicable on all series like the EX series, SRX series, J series, MX series and M series.Monitors the CPU utilization over the last 1, 5 & 15 minutes.[JUNIPER-MIB :: jnxOperating1MinLoadAvg : 1.3.6.1.4.1.2636.3.1.13.1.20, jnxOperating5MinLoadAvg : 1.3.6.1.4.1.2636.3.1.13.1.21, jnxOperating15MinLoadAvg : 1.3.6.1.4.1.2636.3.1.13.1.22]
Prerequisites
Device must have support for JUNIPER-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper CPU Utilization Last 1 & 15 Minutes | juniper_cpu_Operating1MinAvgCPU | Juniper Cpu Utilization last 1 minute | % | Monitors the CPU Utilization over the last 1 minute.[JUNIPER-MIB :: jnxOperating1MinLoadAvg : 1.3.6.1.4.1.2636.3.1.13.1.20] |
juniper_cpu_Operating15MinAvgCPU | Juniper Cpu Utilization last 15 minute | % | Monitors the CPU Utilization over the last 15 minutes in %.[JUNIPER-MIB :: jnxOperating15MinLoadAvg : 1.3.6.1.4.1.2636.3.1.13.1.22] |
Juniper - LED Status
Description
Monitors the state of the LED indicator.[JUNIPER-MIB :: jnxLEDState : 1.3.6.1.4.1.2636.3.1.10.1.8, jnxLEDStateOrdered : 1.3.6.1.4.1.2636.3.1.10.1.9]
Prerequisites
Device must have support for JUNIPER-MIB
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper LED Status | juniper_LEDState | Juniper LED State | Monitors the state of the LED indicator.[JUNIPER-MIB :: jnxLEDState : 1.3.6.1.4.1.2636.3.1.10.1.8].Possible values are other(1),green(2),yellow(3),red(4),blue(5),amber(6),off(7),blinkingGreen(8),blinkingYellow(9),blinkingRed(10),blinkingBlue(11),blinkingAmber(12). | |
juniper_LEDStateOrdered | Juniper LED State Ordered | Monitors the state of the LED indicator with enums ordered from 'most operational' to 'least operational' states.[JUNIPER-MIB :: jnxLEDStateOrdered : 1.3.6.1.4.1.2636.3.1.10.1.9].Possible values are other(1),green(2),yellow(3),red(4),blue(5),amber(6),off(7),blinkingBlue(8),blinkingGreen(9),blinkingAmber(10),blinkingYellow(11),blinkingRed(12) |
Juniper Alarm State - G2
Description
It monitors jnx yellow alarm and jnx red alarm states.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Alarm State | juniper.red.alarm.status | Red Alarm State | The red alarm indication on the craft interface panel. The red alarm is on when there is some system failure or power supply failure or the system is experiencing a hardware malfunction or some threshold is being exceeded. [JUNIPER-ALARM-MIB] [1.3.6.1.4.1.2636.3.4.2.3.1] - Possible values are 1: Other, 2: Off, 3: On. The critical alert will be generated if this oid value = 3(On). The red alarm is on when there is some system failure or power supply failure or the system is experiencing a hardware malfunction or some threshold is being exceeded. | |
juniper.yellow.alarm.status | Yellow Alarm State | The yellow alarm state on the craft interface panel. The yellow alarm is On when there is some system warning such as maintenance alert or significant temperature increase. [JUNIPER-ALARM-MIB] [1.3.6.1.4.1.2636.3.4.2.2.1] - Possible values are 1: Other, 2: Off, 3: On. The warning alert will be generated if this oid value = 3(On). The yellow alarm is on when there is some system warning such as maintenance alert or significant temperature increase. |
Juniper BGP Peer State - G2
Description
It monitors the remote BGP peer’s FSM state.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper BGP Peer Status | juniper.bgp.peer.status.v2 | Junos BGP Peer State | Whether or not the BGP FSM for this remote peer is halted or running. It will generates critical alert only if (remote peer is not in Established state and BGP FSM is not in halted state). Remote peer state oid - [1.3.6.1.4.1.2636.5.1.1.2.1.1.1.2] and BGP FSM oid - [1.3.6.1.4.1.2636.5.1.1.2.1.1.1.3] |
Juniper EX Series - G2
Description
This template is applicable for Juniper EX series. Monitors packet tail drop rate and VLAN interface status.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Interface Packets Tail-drop Rate | juniper.cos.packets.tail.drop.rate | Packets tail drop rate | packets/sec | Indicates the rate of packets tail-dropped at the output queue. Tail drop profile is a congestion management mechanism that allows switch to drop arriving packets when queue buffers become full or begin to overflow. [OID: 1.3.6.1.4.1.2636.3.15.4.1.12] |
Juniper Vlan Interface Status | vlan.interface.status | Vlan Interface Status | Provides the operational status of the vlan when admin status is Up. Possible operational status values are 1 - Up, 2- Down. [OID: 1.3.6.1.4.1.2636.3.40.1.5.1.6.1.6, 1.3.6.1.4.1.2636.3.40.1.5.1.6.1.7, 1.3.6.1.4.1.2636.3.40.1.5.1.5.1.5] |
Juniper Firewall Filter Stats - G2
Description
It monitors the number of packets and bytes being counted pertaining to the specified counter or policer. Reference mib - [JUNIPER-FIREWALL-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Firewall Filter Stats | juniper.fw.counter.bytes | Firewall Counter Bytes | The number of bytes being counted pertaining to the specified counter. For policers, this field is always zero because policers do not count number of bytes. [OIDs: 1.3.6.1.4.1.2636.3.5.2.1.5, 1.3.6.1.4.1.2636.3.5.2.1.6, 1.3.6.1.4.1.2636.3.5.2.1.7] | |
juniper.fw.counter.packets | Firewall Counter Packets | The number of packets being counted pertaining to the specified counter or policer. [1.3.6.1.4.1.2636.3.5.2.1.4] |
Juniper Interface Statistics
Description
Monitors the interface statistics like Input Queue drops, Output Queue Drops and Output Collisions detected on this interface. [using JUNIPER-IF-MIB]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Interface Ext Monitors | juniper.interface.collisions.rate | Interface Output Collisions Rate | psec | Collisions: The rate of output collisions detected on this interface. [OID: 1.3.6.1.4.1.2636.3.3.1.1.25] |
juniper.interface.queue.drops.in | Interface Input Queue Drop Rate | packets/sec | Drops: The rate of packets dropped by the input queue of the I/O Manager ASIC. | |
juniper.interface.queue.drops.out | Interface Output Queue Drop Rate | packets/sec | Drops: The rate of packets dropped by the output queue of the I/O Manager ASIC. [OID: 1.3.6.1.4.1.2636.3.3.1.1.27] |
Juniper LDP Statistics
Description
Monitors Juniper LDP Ingress Octets and Transit Octets.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper LDP Stats | juniper.ldp.ingress.octets | LDP Ingress Octets | Bps | Monitors the number of octets of traffic originated on this box, forwarded over the current LDP FEC. The number reported is not realtime and may be subject to several minutes delay. The delay is controllable by ldp statistics gathering interval, which by default is 5 minutes.[OID: 1.3.6.1.4.1.2636.3.14.2.1.6]. ADDITIONAL INFO: Label Distribution Protocol (LDP) is a protocol for distributing labels in non-traffic-engineered applications. LDP allows routers to establish label-switched paths (LSPs) through a network by mapping network-layer routing information directly to data link layer-switched paths. LDP associates a forwarding equivalence class (FEC) with each LSP it creates. The FEC associated with an LSP specifies which packets are mapped to that LSP. |
juniper.ldp.transit.octets | LDP Transit Octets | Bps | Monitors the number of octets of traffic destined to this FEC, originated on a different box, forwarded over the current LDP FEC. The number reported is not real time and may be subject to several minutes delay. The delay is controllable by ldp statistics gathering interval, which by default is 5 minutes. [OID: 1.3.6.1.4.1.2636.3.14.2.1.8]. ADDITIONAL INFO: Label Distribution Protocol (LDP) is a protocol for distributing labels in non-traffic-engineered applications. LDP allows routers to establish label-switched paths (LSPs) through a network by mapping network-layer routing information directly to data link layer-switched paths. LDP associates a forwarding equivalence class (FEC) with each LSP it creates. The FEC associated with an LSP specifies which packets are mapped to that LSP. |
Juniper MX Series
Description
Applicable on Juniper MX series devices. Monitors Juniper BGP peer status, alarm state and firewall filter statistics.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Alarm State | juniper.red.alarm.status | Red Alarm State | The red alarm indication on the craft interface panel. The red alarm is on when there is some system failure or power supply failure or the system is experiencing a hardware malfunction or some threshold is being exceeded. [JUNIPER-ALARM-MIB] [1.3.6.1.4.1.2636.3.4.2.3.1] - Possible values are 1: Other, 2: Off, 3: On. The critical alert will be generated if this oid value = 3(On). The red alarm is on when there is some system failure or power supply failure or the system is experiencing a hardware malfunction or some threshold is being exceeded. | |
juniper.yellow.alarm.status | Yellow Alarm State | The yellow alarm state on the craft interface panel. The yellow alarm is On when there is some system warning such as maintenance alert or significant temperature increase. [JUNIPER-ALARM-MIB] [1.3.6.1.4.1.2636.3.4.2.2.1] - Possible values are 1: Other, 2: Off, 3: On. The warning alert will be generated if this oid value = 3(On). The yellow alarm is on when there is some system warning such as maintenance alert or significant temperature increase. | ||
Juniper BGP Peer Status | juniper.bgp.peer.status.v2 | Junos BGP Peer State | Whether or not the BGP FSM for this remote peer is halted or running. It will generates critical alert only if (remote peer is not in Established state and BGP FSM is not in halted state). Remote peer state oid - [1.3.6.1.4.1.2636.5.1.1.2.1.1.1.2] and BGP FSM oid - [1.3.6.1.4.1.2636.5.1.1.2.1.1.1.3] | |
Juniper Firewall Filter Stats | juniper.fw.counter.bytes | Firewall Counter Bytes | The number of bytes being counted pertaining to the specified counter. For policers, this field is always zero because policers do not count number of bytes. [OIDs: 1.3.6.1.4.1.2636.3.5.2.1.5, 1.3.6.1.4.1.2636.3.5.2.1.6, 1.3.6.1.4.1.2636.3.5.2.1.7] | |
juniper.fw.counter.packets | Firewall Counter Packets | The number of packets being counted pertaining to the specified counter or policer. [1.3.6.1.4.1.2636.3.5.2.1.4] |
Juniper NetScreen Firewall - G2
Description
Applicable for devices which are using Screen OS. Monitors CPU utilization, memory utilization, session utilization and failed sessions count.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Netscreen Device Health | netscreen.device.health.cpu.utlization | CPU Utilization | % | Monitors the average system CPU utilization. [OID: 1.3.6.1.4.1.3224.16.1.1.0] |
system.memory.util.percent | Memory Utilization | % | Monitors the memory utilization. [OIDs: 1.3.6.1.4.1.3224.16.2.1.0, 1.3.6.1.4.1.3224.16.2.2.0] | |
netscreen.session.failed | Failed Sessions | Monitors failed sessions. [OID: 1.3.6.1.4.1.3224.16.3.4.0] | ||
netscreen.session.utilization | Session Utilization | % | Provides firewall session utilization. [OIDs: 1.3.6.1.4.1.3224.16.3.2.0, 1.3.6.1.4.1.3224.16.3.3.0] |
Juniper OSPF Monitors
Description
Monitors the OSPF router operational status and also monitors the statistics like Rate of OSPF neighbors, Rate of OSPF adjacent neighbors.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Inerface OSPF-Specific Characteristics | juniper.ospf.interface.neighbors.rate | OSPF Neighbors Rate | psec | Monitors the rate of OSPF neighbors from this interface. [OIDs: 1.3.6.1.2.1.14.7.1.1, 1.3.6.1.4.1.4874.2.2.14.1.7.1.4] |
juniper.ospf.interface.adjacent.neighbors.rate | OSPF Adjacent Neighbors Rate | psec | Rate of OSPF adjacent neighbors from this interface. [OIDs: 1.3.6.1.2.1.14.7.1.1,1.3.6.1.4.1.4874.2.2.14.1.7.1.5] | |
Juniper OSPF Router Status | juniper.ospf.router.status | Juniper OSPF Router Operational Status | It checks whether this router is operational/not. [OID: 1.3.6.1.4.1.4874.2.2.14.1.1.35] |
Juniper Power Supply Unit
Description
Monitors the PSU chassis power reserved, power allocated, power consumed, power available in redundant mode, total power available, average power used, temperature and humidity. Also it monitors PSU Outlet parameters like status, power consumed, average power, voltage and current. This template validated on Juniper QFX3000-g devices. [Using JUNIPER-POWER-SUPPLY-UNIT-MIB.mib]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper PSU Chassis Monitors | juniper.psu.units.count | Number of PSU units available online | Represents the number of PSU units available online in the System. [OID: 1.3.6.1.4.1.2636.3.58.1.2.1.1.0] | |
juniper.psu.chassis.reserved.power | Power reserved for Chassis | W | Power reserved for Chassis in Watts. [OID: 1.3.6.1.4.1.2636.3.58.1.2.1.5.0] | |
juniper.psu.chassis.allocated.power | Power allocated for Chassis | W | Total power allocated for chassis and all the FPCs in Watts. [OIDs: 1.3.6.1.4.1.2636.3.58.1.2.1.6.0] | |
juniper.psu.system.consumed.power | Total Power consumed across all PSU units | Total power consumed by the entire system rounded to the nearest integer. This is calculated using the PowerFactor, Current and Voltage values of each PSU that is online and connected to the System. [OID: 1.3.6.1.4.1.2636.3.58.1.2.1.9.0] | ||
juniper.psu.redundant.power.avail | Power Available (Redundant case) | W | Power(in Watts) that is still available for allocation even while supporting redundancy with the present usage. [OID: 1.3.6.1.4.1.2636.3.58.1.2.1.7.0] | |
juniper.psu.total.power.avail | Total Power Available | W | Power available(in Watts) which could be made available for further allocation without supporting any redundancy with the present usage. [OID: 1.3.6.1.4.1.2636.3.58.1.2.1.8] | |
Juniper PSU Environment Monitor | juniper.psu.env.temperature | PSU Environment Temperature | C | Represents the Temparature at each component in degrees Celsius rounded to the nearest integer. [OID: 1.3.6.1.4.1.2636.3.58.1.2.3.1.1] |
juniper.psu.env.humidity | PSU Environment Humidity | % | Humidity at each component in percentage. [OID: 1.3.6.1.4.1.2636.3.58.1.2.3.1.2] | |
Juniper PSU Outlet Monitors | juniper.psu.outlet.status | Power Outlet Status | The value of the operational status for the given outlet. [OID: 1.3.6.1.4.1.2636.3.58.1.2.4.1.8] | |
juniper.psu.outlet.power.consumed | PSU Outlet Power Consumed | W | Power Consumed by each outlet units in Watts. [OID: 1.3.6.1.4.1.2636.3.58.1.2.4.1.11] | |
juniper.psu.outlet.avg.power.used | PSU Outlet Average Power Used | W | Buffer that contains the average power used, in Watts for each component. [OID: 1.3.6.1.4.1.2636.3.58.1.2.4.1.3] | |
juniper.psu.outlet.voltage | PSU Outlet Voltage | v | Output voltage in Volts rounded to the nearest integer. [OID: 1.3.6.1.4.1.2636.3.58.1.2.4.1.9] | |
juniper.psu.outlet.current | PSU Outlet Current | mA | PSU output current in milliamps rounded to the nearest integer. [OID: 1.3.6.1.4.1.2636.3.58.1.2.4.1.5] | |
Juniper PSU Power | juniper.psu.avg.power.used | Average Power Used | W | Buffer that contains the average power used, in Watts for each component. [OID: 1.3.6.1.4.1.2636.3.58.1.2.2.1.1] |
Juniper QFX - Status and Performance Check
Description
Applicable only on QFX series devices. Monitors CPU utilization, memory utilization, buffer utilization, CPU load, temperature, operational state, FRU state and device uptime.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper QFabric - CPU | cpu.utilization | CPU Utilization | % | Monitors the CPU usage. Zero if unavailable or inapplicable |
cpu.load | CPU Load | % | Routing Engine load averages for the last 5 min. This value needs to be correlated with CPU usage. A value lesser than 100 indicates normal operation. A value in the range of 100-300 along with a CPU utilization of greater than 70% could require some investigation. | |
Juniper QFabric - FRU | juniper.fru.state | FRU state | Indicates the FRU state of this subject. Possible states are 1- Unknown 2- Empty 3- Present 4- Ready 5- announceOnline 6- Online 7- anounceOffline 8- offline, 9-diagnostic, 10-standby. | |
juniper.fru.type | Juniper FRU Type | The FRU type for this subject. | ||
juniper.virtualchassis.fru.temperature | Juniper FRU Temperature | C | Monitors the temperature in Celsius (degrees C). The value of this monitor is zero if unavailable or inapplicable. | |
Juniper QFabric - Kernel Memory Utilization | kernel.memory.util | Kernel Memory Utilization | % | The percentage of kernel memory used of this subject. 0 if unavailable or inapplicable. |
Juniper QFabric - Memory | memory.utilization | Memory Utilization | % | Indicates the heap utilization in percentage. Zero if unavailable or inapplicable. |
juniper.buffer.utilization | Buffer utilization | % | The buffer pool utilization in percentage. Zero if unavailable or inapplicable. | |
juniper.buffer.free | Buffer Pool Free | Bytes | Monitors the buffer pool free. | |
Juniper QFabric - Operating State | juniper.operational.state | Operational state | Indicates the operating state of this subject. Possible values are 1- Unknown 2- Running 3- Ready 4- Reset 5- Running at full speed 6- Down 7- Standby. | |
Juniper QFabric - Temperature | system.temperature | Temperature | C | The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable |
Juniper Storage Utilization | juniper.common.app.storageutilization | Storage utilization | % | The amount of the storage used by each file system on the router in percentage. [OIDs: 1.3.6.1.2.1.25.2.3.1.2,1.3.6.1.2.1.25.2.3.1.3, 1.3.6.1.4.1.2636.3.31.1.1.1.1] |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Juniper SA Health - G2
Description
This template is applicable on the Juniper SA series, Secure Access VPN Appliance. Monitors the CPU, Memory, Disk and Swap memory utilization on this appliance. Also monitor the log file used percent and the temperature.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper SA Health Monitor | system.disk.util.percent | Disk Utilization | % | Disk utilization is the percent of disk space used in comparison to the total disk space available. |
system.cpu.utilization | CPU Utilization | % | The CPU Utilization of the IVE system. | |
system.swap.memory.util.percent | Swap Memory Utilization | % | It represents the utilization of Swap Memory. | |
system.memory.util.percent | Memory Utilization | % | The Memory Utilization of the IVE system. | |
Juniper SSL VPN Appliance Monitor | juniper.ssl.vpn.log.file.percent | Log file full percentage | % | Provides the percentage of log file full [OID: 1.3.6.1.4.1.12532.1.0] |
system.temperature | Temperature | C | The Temperature of MAG application blade.[OID: 1.3.6.1.4.1.12532.42.0 ] |
Juniper SA Performance Statistics - G2
Description
This template is applicable for the Juniper SA series, Secure Access VPN Appliance. Monitors performance statistics. Monitors the number of IVE Hits, File Hits, Web hits, and Applet hits on the appliance.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper SA Performance Statistics | juniper.total.ive.hits | Total number of Hits to IVE | The total number of hits to the IVE since last reboot [OID: 1.3.6.1.4.1.12532.14.0] | |
juniper.total.ive.file.hits | Total number of IVE File Hits | The Total number of hits to the IVE since last reboot. [OID: 1.3.6.1.4.1.12532.15.0] | ||
juniper.total.ive.web.hits | Total number of Web Hits | The Total number of hits via the Web Interface since the last reboot. [OID: 1.3.6.1.4.1.12532.16.0] | ||
juniper.total.ive.applet.hits | Total number of Applet Hits | The Total number of applet hits to the IVE since last reboot. [OID: 1.3.6.1.4.1.12532.17.0] |
Juniper SA User Statistics - G2
Description
This template is applicable on the Juniper SA series, Secure Access VPN Appliance. Monitors the number of logged users.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper SA User Statistics | juniper.sa.signedin.web.users | Signed In Web Users | Number of Signed-In Web Users. [OID: 1.3.6.1.4.1.12532.2.0] | |
juniper.sa.signedin.mail.users | Signed In Mail Users | Number of Signed-In Mail Users [OID:1.3.6.1.4.1.12532.3.0] | ||
juniper.sa.ive.concurrent.users | Number of IVE Concurrent users | The Total number of Users Logged in for the IVE Node. [OID: 1.3.6.1.4.1.12532.12.0] | ||
juniper.sa.cluster.concurrent.users | Number of Cluster Concurrent Users | The Total number of Users Logged In for the Cluster [OID: 1.3.6.1.4.1.12532.13.0] |
Juniper SRX Series - G2
Description
This template is applicable for Juniper SRX devices. Monitors SPU utilization, memory utilization, flow/PFE sessions utlization, CP sessions utlization, interface NAT port utilization and source-nat port utilization.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper SRX Interface NAT Port Usage | juniper.srx.nat.singleport.usage | NAT Interface Single Ports usage | % | Amount of Single Ports per Overload Pool in use when using Interface Nat translation. [OID: 1.3.6.1.4.1.2636.3.39.1.7.1.1.3.1.2, 1.3.6.1.4.1.2636.3.39.1.7.1.1.3.1.3] |
juniper.srx.nat.twinports.usage | NAT Interface Twin Ports usage | % | Represents Twin Ports per Overload Pool in use when using Interface Nat translation. [OID: 1.3.6.1.4.1.2636.3.39.1.7.1.1.3.1.4, 1.3.6.1.4.1.2636.3.39.1.7.1.1.3.1.5] | |
Juniper SRX Source-Nat Pool Ports Usage | juniper.srx.sourcenat.port.usage | Source-Nat Pool Ports Usage | Ports utilization when using Source-NatPool with PAT. [OID: 1.3.6.1.4.1.2636.3.39.1.7.1.1.4.1.1, 1.3.6.1.4.1.2636.3.39.1.7.1.1.4.1.5] | |
Juniper SRX SPUs Utilization Statistics | juniper.srx.spu.utilization | SPU utilization | % | Represents the current SPU Usage of Packet Forwarding Engine(PFE). [OID: 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.11, 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.4] |
juniper.srx.spu.memory.util | Memory Utilization | % | Represents Packet Forwarding memory usage. [OIDs: 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.11, 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.5] | |
juniper.srx.cpsession.usage | Central Point(CP) Session Utilization | % | Represents the current central point (CP) session utilization of services processing unit (SPU). OID: [1.3.6.1.4.1.2636.3.39.1.12.1.1.1.8, 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.9, 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.11] | |
juniper.srx.flowsession.usage | Flow/PFE Sessions Utilization | % | Monitors the current flow sessions utilization of services processing unit (SPU) [OID: 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.7, 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.6, 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.11] |
Juniper SSG Firewall - G2
Description
Applicable on all SSG devices. Monitors vpn tunnel. Can be applied on SSG-550 version 6.2.0r10.0 (SN: JN1161AF7ADB, Firewall+VPN). SNMP Obj Id=1.3.6.1.4.1.3224.1.51. . Open TCP ports[80,22,23,443,]. DNS name(R)=10.10.0.120
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Netscreen VPN Tunnel Phases Status | vpn.tunnel.phase2.status | VPN Tunnel Phase2 Status | Monitors the IKE's Phase 2 status. Possible values are 0- inactive, 1- active. [OIDs: 1.3.6.1.4.1.3224.4.1.1.1.4, 1.3.6.1.4.1.3224.4.1.1.1.15, 1.3.6.1.4.1.3224.4.1.1.1.23, 1.3.6.1.4.1.3224.4.1.1.1.24, 1.3.6.1.4.1.3224.4.1.1.1.13] | |
vpn.tunnel.phase1.status | VPN Tunnel Phase1 Status | Monitors the IKE's phase 1 status. Possible values are 0- inactive, 1- active. [OIDs: 1.3.6.1.4.1.3224.4.1.1.1.4, 1.3.6.1.4.1.3224.4.1.1.1.15, 1.3.6.1.4.1.3224.4.1.1.1.13, 1.3.6.1.4.1.3224.4.1.1.1.21, 1.3.6.1.4.1.3224.4.1.1.1.22] |
Juniper Standard Status and Performance Check - G2
Description
Applicable on all series like the EX series, SRX series, J series, MX series and M series. Monitors CPU utilization, memory utilization, buffer utilization, CPU load, temperature, operational state, FRU state and device uptime.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper CPU Monitor | cpu.utilization | CPU Utilization | % | Monitors CPU usage by the Routing Engine. Zero if unavailable or inapplicable |
cpu.load | CPU Load | % | Routing Engine load averages for the last 5 min. This value needs to be correlated with CPU usage. A value lesser than 100 indicates normal operation. A value in the range of 100-300 along with a CPU utilization of greater than 70% could require some inv. | |
Juniper FRU Status | juniper.fru.state | FRU state | Represents the FRU state. Possible states are 1- Unknown 2- Empty, 3- Present, 4- Ready 5- AnnounceOnline, 6- Online, 7- AnnounceOffline, 8- Offline, 9- Diagnostic, 10- Standby. [OIDs: 1.3.6.1.4.1.2636.3.1.15.1.5, 1.3.6.1.4.1.2636.3.1.15.1.6, 1.3.6.1.4.1.2636.3.1.15.1.8, 1.3.6.1.4.1.2636.3.1.15.1.9]. | |
juniper.fru.type | Juniper FRU Type | The FRU type for this subject. [OID: 1.3.6.1.4.1.2636.3.1.15.1.6] | ||
Juniper FRU Temperature | juniper.virtualchassis.fru.temperature | Juniper FRU Temperature | C | Monitors the temperature in Celsius (degrees C) of this juniper switch. The value of this monitor is zero if unavailable or inapplicable. [OIDs: 1.3.6.1.4.1.2636.3.1.15.1.5, 1.3.6.1.4.1.2636.3.1.15.1.9] |
Juniper Kernel Memory Utilization | kernel.memory.util | Kernel Memory Utilization | % | The percentage of kernel memory used of this subject. 0 if unavailable or inapplicable. [OID: 1.3.6.1.4.1.2636.3.1.16.0] |
Juniper Memory Monitor | memory.utilization | Memory Utilization | % | Indicates the heap utilization and memory size. Zero if unavailable or inapplicable. [OIDs: 1.3.6.1.4.1.2636.3.1.13.1.12, 1.3.6.1.4.1.2636.3.1.13.1.15] |
juniper.buffer.utilization | Buffer utilization | % | The buffer pool utilization in percentage. Zero if unavailable or inapplicable [1.3.6.1.4.1.2636.3.1.13.1.5, 1.3.6.1.4.1.2636.3.1.13.1.11] | |
juniper.buffer.free | Buffer Pool Free | Bytes | Monitors the buffer pool free. [OID: 1.3.6.1.4.1.2636.3.1.13.1.11, 1.3.6.1.4.1.2636.3.1.13.1.15] | |
Juniper Operational Status | juniper.operational.state | Operational state | Indicates the operating state of this subject. Possible values are 1- Unknown 2- Running 3- Ready 4- Reset 5- Running at full speed 6- Down 7- Standby [OID: 1.3.6.1.4.1.2636.3.1.13.1.5, 1.3.6.1.4.1.2636.3.1.13.1.6] | |
Juniper Storage Utilization | juniper.common.app.storageutilization | Storage utilization | % | The amount of the storage used by each file system on the router in percentage. [OIDs: 1.3.6.1.2.1.25.2.3.1.2,1.3.6.1.2.1.25.2.3.1.3, 1.3.6.1.4.1.2636.3.31.1.1.1.1] |
Juniper Temperature Monitor | system.temperature | Temperature | C | Indicates the temperature sensor value. [OID: 1.3.6.1.4.1.2636.3.1.13.1.7] |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Juniper Standard Status and Performance Check - V2
Description
Applicable on all series like the EX series, SRX series, J series, MX series and M series. Monitors CPU utilization, memory utilization, buffer utilization, CPU load, temperature, operational state, FRU state and device uptime.
Note: This template is an alternative to the juniper Standard Status and Performance Check - G2, and the poll interval has been decreased to 5 minutes.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper FRU Temperature | juniper.virtualchassis.fru.temperature | Juniper FRU Temperature | C | Monitors the temperature in Celsius (degrees C) of this juniper switch. The value of this monitor is zero if unavailable or inapplicable. [OIDs: 1.3.6.1.4.1.2636.3.1.15.1.5, 1.3.6.1.4.1.2636.3.1.15.1.9] |
Juniper Temperature Monitor | system.temperature | Temperature | C | Indicates the temperature sensor value. [OID: 1.3.6.1.4.1.2636.3.1.13.1.7] |
Juniper FRU Status | juniper.fru.type | Juniper FRU Type | The FRU type for this subject. [OID: 1.3.6.1.4.1.2636.3.1.15.1.6] | |
juniper.fru.state | FRU state | Represents the FRU state. Possible states are 1- Unknown 2- Empty, 3- Present, 4- Ready 5- AnnounceOnline, 6- Online, 7- AnnounceOffline, 8- Offline, 9- Diagnostic, 10- Standby. [OIDs: 1.3.6.1.4.1.2636.3.1.15.1.5, 1.3.6.1.4.1.2636.3.1.15.1.6, 1.3.6.1.4.1.2636.3.1.15.1.8, 1.3.6.1.4.1.2636.3.1.15.1.9]. | ||
Juniper Memory Monitor | memory.utilization | Memory Utilization | % | Indicates the heap utilization and memory size. Zero if unavailable or inapplicable. [OIDs: 1.3.6.1.4.1.2636.3.1.13.1.12, 1.3.6.1.4.1.2636.3.1.13.1.15] |
juniper.buffer.utilization | Buffer utilization | % | The buffer pool utilization in percentage. Zero if unavailable or inapplicable. [1.3.6.1.4.1.2636.3.1.13.1.5, 1.3.6.1.4.1.2636.3.1.13.1.11] | |
juniper.buffer.free | Buffer Pool Free | Bytes | Monitors the buffer pool free. [OID: 1.3.6.1.4.1.2636.3.1.13.1.11, 1.3.6.1.4.1.2636.3.1.13.1.15] | |
Juniper CPU Monitor | cpu.utilization | CPU Utilization | % | Monitors CPU usage by the Routing Engine. Zero if unavailable or inapplicable |
cpu.load | CPU Load | % | Routing Engine load averages for the last 5 min. This value needs to be correlated with CPU usage. A value lesser than 100 indicates normal operation. A value in the range of 100-300 along with a CPU utilization of greater than 70% could require some inv. | |
Juniper Operational Status | juniper.operational.state | Operational state | Indicates the operating state of this subject. Possible values are 1- Unknown 2- Running 3- Ready 4- Reset 5- Running at full speed 6- Down 7- Standby [OID: 1.3.6.1.4.1.2636.3.1.13.1.5, 1.3.6.1.4.1.2636.3.1.13.1.6] | |
Juniper Storage Utilization | juniper.common.app.storageutilization | Storage utilization | % | The amount of the storage used by each file system on the router in percentage. [OIDs: 1.3.6.1.2.1.25.2.3.1.2,1.3.6.1.2.1.25.2.3.1.3, 1.3.6.1.4.1.2636.3.31.1.1.1.1] |
Juniper Kernel Memory Utilization | kernel.memory.util | Kernel Memory Utilization | % | The percentage of kernel memory used of this subject. 0 if unavailable or inapplicable. [OID: 1.3.6.1.4.1.2636.3.1.16.0] |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized. [OID : 1.3.6.1.2.1.1.3.0] |
Juniper Virtual Chassis Port Status
Description
Template to monitor the actual operational status of this Virtual Chassis Control Protocol (vccp) port. Tested on Juniper qfx5100-24q-2p Ethernet Switch. [SysObjID: 1.3.6.1.4.1.2636.1.1.1.4.82.4]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper Virtual Chassis Port Status | juniper.virtualchassis.port.status | Vitual Chassis Port Status | Indicates the actual operational status of this vccp port, which is typically but not limited to, a function of the state of individual segments of this port. [OID: 1.3.6.1.4.1.2636.3.40.1.4.1.2.1.4] |
Juniper VPLS Monitors
Description
Monitors the VPLS BGP RT Row Status, VPLS BGP VE Row Status, VPLS config row status, peer count, operational status, bgp auto discovery row status and VPLS PW Bind Row Status.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper VPLS BGP RT Row Status | juniper.vpls.bgprte.row.status | VPLS BGP Route Target Row Status | Monitors the VPLS BGP route target row status. Possible values are 1- active: which indicates that the conceptual row is available for use by the managed device, 2- notInService: which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device, 3- notReady: which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device, 4- createAndGo: which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device, 5- createAndWait: which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device), 6- destroy: which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. [OIDs: 1.3.6.1.4.1.2636.5.8.1.2.1.2, .3.6.1.4.1.2636.5.8.1.2.1.4, 1.3.6.1.4.1.2636.5.8.1.6.1.3, 1.3.6.1.4.1.2636.5.8.1.6.1.4] | |
Juniper VPLS BGP VE Row Status | juniper.vpls.bgpve.row.status | VPLS BGP VE Row Status | Monitors the VPLS BGP edge device row status. Possible values are 1- active: which indicates that the conceptual row is available for use by the managed device, 2- notInService: which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device, 3- notReady: which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device, 4- createAndGo: which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device, 5- createAndWait: which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device), 6- destroy: which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. [OIDs: 1.3.6.1.4.1.2636.5.8.1.2.1.2, .3.6.1.4.1.2636.5.8.1.2.1.4, 1.3.6.1.4.1.2636.5.10.1.2.1.2, 1.3.6.1.4.1.2636.5.10.1.2.1.5] | |
Juniper VPLS Configuration Attributes | juniper.vpls.config.row.status | VPLS Configuration Row Status | Monitors the VPLS configuration row status. Possible values are 1- active: which indicates that the conceptual row is available for use by the managed device, 2- notInService: which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device, 3- notReady: which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device, 4- createAndGo: which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device, 5- createAndWait: which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device), 6- destroy: which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. [OIDs: 1.3.6.1.4.1.2636.5.8.1.2.1.2, 1.3.6.1.4.1.2636.5.8.1.2.1.4, 1.3.6.1.4.1.2636.5.8.1.2.1.12] | |
juniper.vpls.peer.count | VPLS Peer Count | Monitors the the number of peers present in this vpls instance. [OIDs: 1.3.6.1.4.1.2636.5.8.1.2.1.2, 1.3.6.1.4.1.2636.5.8.1.2.1.4, 1.3.6.1.4.1.2636.5.8.1.3.1.2] | ||
juniper.vpls.oper.status | VPLS Operational Status | Monitors the current operational state of this VPLS Service. [OIDs: 1.3.6.1.4.1.2636.5.8.1.2.1.2, 1.3.6.1.4.1.2636.5.8.1.2.1.4, 1.3.6.1.4.1.2636.5.8.1.3.1.1] | ||
juniper.vpls.bgpadc.row.status | VPLS BGP Auto Discovery Row Status | Monitors the VPLS BGP auto discovery config row status. Possible values are 1- active: which indicates that the conceptual row is available for use by the managed device, 2- notInService: which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device, 3- notReady: which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device, 4- createAndGo: which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device, 5- createAndWait: which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device), 6- destroy: which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. [OID: 1.3.6.1.4.1.2636.5.8.1.5.1.4] | ||
Juniper VPLS PW Bind Row Status | juniper.vpls.pwbind.row.status | VPLS PW Bind Row Status | Monitors the Pseudo Wires bind row status. Possible values are 1- active: which indicates that the conceptual row is available for use by the managed device, 2- notInService: which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device, 3- notReady: which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device, 4- createAndGo: which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device, 5- createAndWait: which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device), 6- destroy: which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. [OIDs: 1.3.6.1.4.1.2636.5.8.1.4.1, 1.3.6.1.4.1.2636.5.8.1.4.1.5, 1.3.6.1.4.1.2636.5.8.1.2.1.2, .3.6.1.4.1.2636.5.8.1.2.1.4] |
Juniper VPN Phase 1 (IKE) Tunnel Status
Description
Template to monitor Juniper VPN Phase 1 (IKE) tunnel peer status. Validated on SRX Firewall, SysObjId is 1.3.6.1.4.1.2636.1.1.1.2.35 [JUNIPER-IPSEC-FLOW-MON-MIB::jnxIkeTunMonState - 1.3.6.1.4.1.2636.3.52.1.1.2.1.6]
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Juniper VPN Phase 1 (IKE) Tunnel Status | juniper.vpn.ike.tunnel.status | VPN Phase 1 (IKE) Tunnel Status | Monitors the Juniper VPN Phase-1 (IKE) Tunnel Status. [OID: 1.3.6.1.4.1.2636.3.52.1.1.2.1.6] |