This page lists the metrics collected by the VMware NSX-V integration and describes the default monitoring configuration applied when the integration is installed.
You can use this information to understand what is monitored out-of-the-box and how to customize thresholds, templates, and alert behaviour for your environment.

Supported Metrics

The metrics collected by the integration are grouped into logical categories based on the monitored component type. Each category is represented as a tabbed table that displays the native type, metric names, display labels, units, supported versions, and descriptions.

Availability
Usage
Native TypeMetric NameDisplay NameUnitsVersionDescriptionMetric Group
NSX-V Managernsxv_manager_UpTimeNSXV Manager UpTimeh2.0.0The appliance uptime.
nsxv_manager_ServerServiceStatusNSXV Manager Server Services StatusNA2.0.0The status of services running on the VMware NSX Manager.Possible Values: 0-NOT_RUNNING, 1-RUNNING
nsxv_manager_VCenterConnectedNSXV Manager VCenter ConnectedNA2.0.0The vCenter Server connection status. Possible values: 0-False, 1-True
NSX-V Controllernsxv_controller_StatusNSXV Controller StatusNA2.0.0The status of the VMware NSX controller. Possible Values: 0-NOT_RUNNING, 1-RUNNING
NSX-V Edgensxv_edge_StateNSXV Edge StateNA2.0.0The state of the gateway.Possible Values: 1-Deployed
nsxv_edge_EdgeStatusNSXV Edge EdgeStatusNA2.0.0The status of the edge. Possible Values: 1-GREEN, 2-YELLOW, 3-RED, 4-GREY
NSX-V Edge Firewallnsxv_edgeFirewall_TCPTimeoutCloseNSXV Edge Firewall TCP Timeout Closes2.0.0The Edge Firewall configuration for TCP timeout to close.
nsxv_edgeFirewall_UDPTimeOutNSXV Edge Firewall UDP Timeouts2.0.0The Edge Firewall configuration for UDP timeout.
nsxv_edgeFirewall_ICMPTimeOutNSXV Edge Firewall ICMP Timeouts2.0.0The Edge Firewall configuration for ICMP timeout.
nsxv_edgeFirewall_ICMP6TimeOutNSXV Edge Firewall ICMP6 Timeouts2.0.0NSXV Edge Firewall ICMP6 Timeout
nsxv_edgeFirewall_IPGenericTimeOutNSXV Edge Firewall IP Genreric Timeouts2.0.0The Edge Firewall configuration for IP generic timeout.
nsxv_edgeFirewall_TCPTimeoutOpenNSXV Edge Firewall TCP Timeout Opens2.0.0The Edge Firewall configuration for TCP timeout to open.
nsxv_edgeFirewall_TCPAllowOutOfWindowPacketsNSXV Edge Firewall TCP Allow Out Of Window PacketsNA2.0.0The Edge Firewall configuration for TCP allow out of window packets status. Possible values: 0-False, 1-True
nsxv_edgeFirewall_TCPPickOngoingConnectionsNSXV Edge Firewall TCP Pick Ongoing ConnectionsNA2.0.0The Edge Firewall configuration for TCP pick ongoing connections status. Possible values: 0-False, 1-True
nsxv_edgeFirewall_TCPSendResetForClosedVsePortsNSXV Edge Firewall TCP Send Reset For Closed Vse PortsNA2.0.0The Edge Firewall configuration for TCP send reset for closed VSE ports status. Possible values: 0-False, 1-True
NSX-V Edge VNICnsxv_edgeVnic_EnableSendRedirectsNSXV Edge VNIC Enable Send RedirectsNA2.0.0NSXV Edge VNIC Enable Send Redirects
nsxv_edgeVnic_IsConnectedNSXV Edge VNIC Is ConnectedNA2.0.0The connection state of the VNIC. Possible values: 0-False, 1-True
nsxv_edgeVnic_EnableProxyArpNSXV Edge VNIC Enable Proxy ArpNA2.0.0Enabled state of proxy ARP on VNIC. Possible values: 0-False, 1-True
Native TypeMetric NameDisplay NameUnitsVersionDescriptionMetric Group
NSX-V Managernsxv_resource_APIStatsNSXV Resource API StatisticsNA2.0.0Provides the number of API calls made within the frequency and resources
nsxv_manager_UsedCPUCapacityNSXV Manager Used CPU CapacityMHz2.0.0The amount of used CPU capacity on the VMware NSX Manager
nsxv_manager_FreeCPUCapacityNSXV Manager Free CPU CapacityMHz2.0.0The amount of free CPU capacity on the VMware NSX Manager
nsxv_manager_CPUUtilizationNSXV Manager CPU Capacity Utilization%2.0.0The percentage of CPU capacity utilization on the VMware NSX Manager
nsxv_manager_CPUUsageIndicatorNSXV Manager CPU Usage IndicatorNA2.0.0The CPU utilization status on the VMware NSX Manager. Possible values: 0-Low, 1-High
nsxv_manager_UsedMemoryNSXV Manager Used MemoryMB2.0.0The amount of used memory on the VMware NSX Manager
nsxv_manager_FreeMemoryNSXV Manager Free MemoryMB2.0.0The amount of free memory on the VMware NSX Manager
nsxv_manager_MemoryUtilizationNSXV Manager Memory Utilization%2.0.0The percentage of memory utilization on the VMware NSX Manager
nsxv_manager_UsedStorageNSXV Manager Used StorageGB2.0.0The amount of used storage on the VMware NSX Manager
nsxv_manager_FreeStorageNSXV Manager Free StorageGB2.0.0The amount of free storage on the VMware NSX Manager
nsxv_manager_StorageUtilizationNSXV Manager Storage Utilization%2.0.0The percatage of storage utlization on the VMware NSX Manager
NSX-V Edge VNICnsxv_edgeVnic_MTUNSXV Edge VNIC MTUcount2.0.0The MTU on the VNIC.

Default Monitoring Configuration

VMware NSX-V provides default monitoring components that include:

  • Global Device Management Policies
  • Global Templates
  • Global Monitors

These configurations are applied automatically upon installation. Customize them for your environment by cloning the global versions and modifying thresholds or alerting behaviour.

It is recommended to perform this customization before installing the application to avoid unnecessary alerts and noise.

Default Global Device Management Policies

Find the Device Management Policy for each Native Type at Setup > Resources > Device Management Policies. Search using the suggested name in global scope:

{appName nativeType - version}

Example: vmware-nsx-v NSX-V Manager - 2

  • appName = vmware-nsx-v
  • nativeType = NSX-V Manager
  • version = 2

Default Global Templates

Templates are available at Setup > Monitoring > Templates. Search using the suggested name in global scope:
{appName nativeType 'Template' - version}

Example: vmware-nsx-v NSX-V Manager Template - 2

  • appName = vmware-nsx-v
  • nativeType = NSX-V Manager
  • version = 2

Default Global Monitors

Monitors can be found at Setup > Monitoring > Monitors. Search using the suggested name in global scope:

{monitorKey appName nativeType - version}

Example: NSX-V Manager Monitor vmware-nsx-v NSX-V Manager 2

  • monitorKey = NSX-V Manager Monitor
  • appName = vmware-nsx-v
  • nativeType = NSX-V Manager
  • version = 2