Supported Metrics

Native TypeMetric NamesDisplay NameMetric LabelUnitVersionDescription
HPE OneView Resourcehpe_oneview_resource_alert_statisticsHPE OneView Resource Alert Statistics1.0.0HPE OneView Resource Alert Statistics.
hpe_oneview_resource_APIStatsHPE OneView Resource API StatisticsUsage1.0.0HPE OneView Resource Alert Statistics.
hpe_oneview_resource_CpuSpeedHPE Oneview Resource CPU SpeedPerformanceHz2.0.0CPU clock speed of the appliance.
hpe_oneview_resource_LanDataTransferRateHPE Oneview Resource Lan Data Transfer RatePerformanceMBps2.0.0Lan Data transfer rate
hpe_oneview_resource_ActiveUpTimeHPE Oneview Resource Active Uptimem2.0.0Uptime of the active appliance.
hpe_oneview_resource_StandByUpTimeHPE Oneview Resource Standby Uptimem2.0.0Uptime of the standby appliance.
hpe_oneview_resource_ControllerStateHPE Oneview Resource Controller StateAvailability2.0.0The current state of the appliance.
Possible values are - CONFIGURATION_ERROR(0), ERROR(1),
FACTORY_RESET(2),FAILOVER(3),INCOMPATIBLE_MODEL_ERROR(4),
NETWORK_ERROR(5),RESTORE(6),
RESTORE_NO_RESET_ERROR(7),STOPPED(8),UPGRADE(9),STARTING(10),OK(11)
HPE OneView Enclosurehpe_oneview_enclosure_HealthStatusHPE OneView Enclosure Health StatusAvailability1.0.0Overall health status of the crossbar.
Possible values are: OK - 0, Disabled - 1,
Warning - 2, Critical -3 , Unknown - 4.
hpe_oneview_enclosure_AmbientTemperatureHPE OneView Enclosure Ambient TemperatureThermalCelsius1.0.0Inlet air temperature in degrees Celsius during this sample interval.
hpe_oneview_enclosure_AvgPowerHPE OneView Enclosure Avg PowerPowerWatts1.0.0Average power consumption in Watts during this sample interval.
hpe_oneview_enclosure_DeratedCapacityHPE OneView Enclosure Derated CapacityUsageWatts1.0.0Enclosure dynamic power cap derated capacity setting in Watts during this sample interval.
hpe_oneview_enclosure_PeakPowerHPE OneView Enclosure Peak PowerPowerWatts1.0.0Peak power consumption in Watts during this sample interval.
hpe_oneview_enclosure_PowerCapHPE OneView Enclosure PowerCapPowerWatts1.0.0Dynamic power cap setting on the server hardware in Watts during this sample interval.
hpe_oneview_enclosure_RatedCapacityHPE OneView Enclosure Rated CapacityUSageWatts1.0.0Enclosure dynamic power cap rated capacity setting in Watts during this sample interval.
HPE OneView Enclosure Interconnecthpe_oneview_interconnectbay_ChangeStateHPE OneView InterconnectBay Change State2.0.0The change state of the interconnect bay.
Possible values are: None - 0,Insert - 1,
ProcessingInsert - 2,Remove - 3
hpe_oneview_interconnectbay_CPUUtilizationHPE OneView InterconnectBay CPU UtilizationUsage%2.0.0Interconnect Bay CPU Utilization
hpe_oneview_interconnectbay_MemoryHPE OneView InterconnectBay MemoryMB2.0.0Interconnect Bay Memory
hpe_oneview_interconnectbay_TemperatureHPE OneView InterconnectBay TemperatureThermalF2.0.0Interconnect Bay Temperature
hpe_oneview_interconnectbay_PowerAverageWattsHPE OneView InterconnectBay Power Average WattsUsageW2.0.0Interconnect Bay Power Average Watts
hpe_oneview_interconnectbay_PowerPeakWattsHPE OneView InterconnectBay Power Peak WattsUsageW2.0.0Interconnect Bay Power Peak Watts.
hpe_oneview_interconnectbay_PowerMinimumWattsHPE OneView InterconnectBay Power Minumum WattsUsageW2.0.0Interconnect Bay Power Minumum Watts.
hpe_oneview_interconnectbay_PowerAllocatedWattsHPE OneView InterconnectBay Power Allocated WattsUsageW2.0.0Interconnect Bay Power Allocated Watts.
hpe_oneview_interconnectbay_PortInDiscardsHPE OneView InterconnectBay Port In DiscardsPerformancecount2.0.0Port statistics IF in discards.
hpe_oneview_interconnectbay_PortOutDiscardsHPE OneView InterconnectBay Port Out Discardscount2.0.0Port statistics IF out discards.
hpe_oneview_interconnectbay_PortInErrorsHPE OneView InterconnectBay Port In ErrorsPerformancecount2.0.0Port statistics IF in errors
hpe_oneview_interconnectbay_PortOutErrorsHPE OneView InterconnectBay Port Out ErrorsPerformancecount2.0.0Port statistics IF out errors
hpe_oneview_interconnectbay_CrcAlignErrorsHPE OneView InterconnectBay CRC Align ErrorsPerformancecount2.0.0Port statistics CRC align errors
hpe_oneview_interconnectbay_CPUUsageHPE OneView InterconnectBay CPU UsageUsage%2.0.0The CPU usage statistic for interconnect module
hpe_oneview_interconnectbay_MemoryUsageHPE OneView InterconnectBay Memory UsageUsage%2.0.0The memory usage statistic for interconnect module
hpe_oneview_interconnectbay_PortStatusHPE OneView InterconnectBay Port StatusAvailability3.0.0Port status.
Possible values are - Linked :0, Unknown :1,
Unlinked :2
hpe_oneview_interconnectbay_PortHealthStatusHPE OneView InterconnectBay Port Health StatusAvailability3.0.0Port health status.
Possible values are - Disabled(0), Error(1),
Normal(2), Warning(3)
hpe_oneview_interconnectbay_PortOverallHealthStatusHPE OneView InterconnectBay Port Overall Health StatusAvailability3.0.0Overall health status of port resource.
Possible values are: OK(0), Disabled(1),
Warning(2), Critical(3), Unknown(4)
HPE OneView Enclosure PowerSupplyhpe_oneview_powersupplybay_StatusHPE OneView PowersupplyBay StatusAvailability1.0.0Overall health status of the power supply.
Possible values are: OK - 0, Disabled - 1,
Warning - 2, Critical -3 , Unknown - 4.
hpe_oneview_powersupplybay_DevicePresenceHPE OneView PowersupplyBay Device PresenceAvailability1.0.0Indicates whether a power supply is present.
Possible values are: Absent - 0, PresenceNoOp - 1,
PresenceUnknown - 2, Subsumed - 3, Present - 4.
HPE OneView Enclosure Fanhpe_oneview_fanbay_DevicePresenceHPE OneView FanBay Device PresenceAvailability1.0.0Indicates whether a fan is present.
Possible values are: Absent - 0, PresenceNoOp - 1,
PresenceUnknown - 2, Subsumed - 3, Present - 4.
hpe_oneview_fanbay_StateHPE OneView FanBay StateAvailability1.0.0Current state of the fan.
Possible values are: Degraded - 0, Failed - 1,
Misplaced - 2, Missing - 3, OK - 4.
hpe_oneview_fanbay_StatusHPE OneView FanBay StatusAvailability1.0.0Overall health status of the fan.
Possible values are: OK - 0, Disabled - 1,
Warning - 2, Critical - 3 , Unknown - 4.
HPE OneView Enclosure ManagerBayhpe_oneview_managerbay_RoleHPE OneView ManagerBay Role1.0.0The current role of the manager.
Possible values are: Active - 0, Standby - 1,
Transition - 2, Unknown - 3.
hpe_oneview_managerbay_PowerStateHPE OneView ManagerBay PowerStatePower1.0.0The power state of the manager bay.
Possible values are: Unknown - 1.
hpe_oneview_managerbay_StateHPE OneView Managerbay StateAvailability1.0.0The state of the manager.
Possible values are : Offline - 0, Online - 1.
HPE OneView Appliancehpe_oneview_appliance_StatusHPE OneView Appliance StatusAvailability2.0.0The hardware status of the appliance.
Possible values are OK(0), Disabled(1),
Warning(2), Critical(3) , Unknown(4)
hpe_oneview_appliance_StateHPE OneView Appliance StateAvailability2.0.0Current state of the resource.
Possible values are Unknown(0), Removing(1),
Adding(2), Synchronizing(3), Ok(4)
hpe_oneview_appliance_PoweredOnHPE OneView Appliance PoweredOnPower2.0.0True(1) if the appliance is powered on; false(0) otherwise.
HPE OneView Server Hardwarehpe_oneview_serverhw_PowerStateHPE OneView Server hardware Power StateAvailability1.0.0Current power state of the physical server hardware.
Possible values are: Unknown - 5, On - 0, Off - 1,
PoweringOn - 2, PoweringOff - 3, Resetting - 4.
hpe_oneview_serverhw_HealthStatusHPE OneView Server hardware Health StatusAvailability1.0.0Overall health status of the resource.
Possible values are: OK - 0, Disabled - 1,
Warning - 2, Critical -3, Unknown - 4.
hpe_oneview_serverhw_AmbientTemperatureHPE OneView Server hardware Ambient TemperatureUsageCelsius1.0.0Inlet air temperature in degrees Celsius.
hpe_oneview_serverhw_AvgPowerHPE OneView Server hardware Avg PowerUsageWatts1.0.0Average power consumption in Watts.
hpe_oneview_serverhw_PeakPowerHPE OneView Server hardware Peak PowerUsageWatts1.0.0Peak power consumption in Watts.
hpe_oneview_serverhw_PowerCapHPE OneView Server hardware Power capUsageWatts1.0.0Dynamic power cap setting on the server hardware in Watts.
hpe_oneview_serverhw_CpuAvgFrequencyHPE OneView Server hardware CpuAvgFrequencyUsageMHz1.0.0Average CPU frequency in Mhz.
hpe_oneview_serverhw_CpuUtilizationHPE OneView Server hardware CpuUtillizationUsage%1.0.0CPU utilization of all CPUs in percent.
HPE OneView Storage Systemhpe_oneview_storagesystem_AllocatedCapacityHPE OneView Storagesysten Allocated CapacityUsageBytes1.0.0Allocated capacity of the storage system in bytes.
hpe_oneview_storagesystem_TotalCapacityHPE OneView Storagesystem Total CapacityUsageBytes1.0.0Total capacity of the storage system in bytes.
hpe_oneview_storagesystem_FreeCapacityHPE OneView Storagesystem Free CapacityUsageBytes1.0.0Free capacity of the storage system in bytes.
hpe_oneview_storagesystem_StateHPE OneView Storagesystem StateAvailability1.0.0Current state of the resource.
Possible values are: AddFailed - 0, Adding - 1,
Configured - 2, Connected - 3, Copying - 4, CreateFailed - 5, Creating - 6,
DeleteFailed - 7, Deleting - 8, Discovered - 9, Managed - 10,
Normal - 11, UpdateFailed - 12, Updating - 13.
hpe_oneview_storagesystem_HealthStatusHPE OneView Storagesystem HealthStatusAvailability1.0.0Overall health status of the Storage system resource.
Possible values are: OK - 0, Unknown - 1,
Disabled - 2, Warning - 3, Critical -4.
HPE OneView Storage System Porthpe_oneview_storagesystemport_ConnectionStateHPE OneView Storagesystem port Connection StateAvailability1.0.0Indicates the connection state of the port as reported by the storage system.
Possible values are: Connected - 0, Failed -1,
NotConnected - 2, Offline -3, Unknown - 4.
hpe_oneview_storagesystemport_HealthStatusHPE OneView Storagesystem port healthStatusAvailability1.0.0Overall health status of the port. Possible values are: OK - 0, Disabled -1, Unknown - 2, Warning -3, Critical - 4.
HPE OneView Storage Poolhpe_oneview_storagepool_StateHPE OneView Storagepool StateAvailability1.0.0Current state of the storage pool. Possible values are: AddFailed - 0, Adding - 1, Configured - 2,Connected - 3,Copying - 4, CreateFailed - 5, Creating - 6, DeleteFailed - 7, Deleting - 8,Discovered - 9, Managed - 10, Normal -11, UpdateFailed - 12, Updating - 13.
hpe_oneview_storagepool_HealthStatusHPE OneView Storagepool HealthStatusAvailability1.0.0Overall health status of the storage pool. OK - 0, Disabled - 1, Unknown - 2, Warning - 3, Critical - 4.
hpe_oneview_storagepool_FreeCapacityHPE OneView Storagepool Free CapacityUsageBytes1.0.0Free capacity available from the storage pool in bytes.
hpe_oneview_storagepool_TotalCapacityHPE OneView Storagepool Total CapacityUsageBytes1.0.0Total capacity of the storage pool in bytes.
hpe_oneview_storagepool_SubscribedCapacityHPE OneView Storagepool Subscribed CapacityUsageBytes1.0.0Storage pool subscribed capacity in Bytes.
hpe_oneview_storagepool_TotalAllocatedCapacityHPE OneView Storagepool Total Allocated CapacityUsageBytes1.0.0The total allocated capacity of the pool in bytes..
hpe_oneview_storagepool_VolumeAllocatedCapacityHPE OneView Storagepool Volume Allocated CapacityUsageBytes1.0.0The pool capacity allocated to volumes in bytes.
hpe_oneview_storagepool_SnapshotAllocatedCapacityHPE OneView Storagepool Snapshot Allocated CapacityUsageBytes1.0.0The pool capacity allocated to snapshots in bytes.
HPE OneView Server Profilehpe_oneview_serverprofile_StatusHPE OneView Server Profile StatusAvailability3.0.0Overall health status of this server profile. Possible values are : OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4).
hpe_oneview_serverprofile_StateHPE OneView Server Profile StateAvailability3.0.0Current state of the server profile.Possible values are : Normal(0), Creating(1) , CreateFailed(2), Updating(3), UpdateFailed(4), Deleting(5), DeleteFailed(6)
HPE OneView Drive Enclosurehpe_oneview_driveEnclosure_PowerStateHPE OneView Drive Enclosure Power StateAvailability3.0.0Current power state of drive enclosure. Possible values are: Off(0), On(1), PoweringOff(2), PoweringOn(3) , Unknown(4)
hpe_oneview_driveEnclosure_StatusHPE OneView Drive Enclosure StatusAvailability3.0.0Overall health status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
HPE OneView Drive Bayhpe_oneview_driveBay_StatusHPE OneView Drive Bay StatusAvailability3.0.0Overall health status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
HPE OneView Drivehpe_oneview_drive_StatusHPE OneView Drive StatusAvailability3.0.0Overall health status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
HPE OneView Drive Enclosure IOAdapterhpe_oneview_driveEnclosure_IoAdapter_StatusHPE OneView Drive Enclosure IoAdapter StatusAvailability3.0.0Overall health status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
hpe_oneview_driveEnclosure_IoAdapter_port_StatusHPE OneView Drive Enclosure IoAdapter Port StatusAvailability3.0.0Overall health status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
HPE OneView Logical JBOD Attachmenthpe_oneview_logicalJBODAttachment_StatusHPE OneView Logical JBOD Attachment StatusAvailability3.0.0Overall health status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
HPE OneView Logical JBODhpe_oneview_logicalJBOD_StatusHPE OneView Logical JBOD StatusAvailability3.0.0Overall health status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
HPE OneView SANhpe_oneview_san_StateHPE OneView SAN StateAvailability3.0.0State of the SAN resource. Possible values are: ConfigurationPending(0), Configured(1), Configuring(2), Deleting(3), Discovered(4), Managed(5), Removing(6)
hpe_oneview_san_StatusHPE OneView SAN StatusAvailability3.0.0Status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)
HPE OneView SAN Managerhpe_oneview_sanManager_StateHPE OneView SAN Manager StateAvailability3.0.0State of the SAN manager resource. Possible values are: ConfigurationPending(0), Configured(1), Configuring(2), Deleting(3), Discovered(4), Managed(5), Removing(6)
hpe_oneview_sanManager_StatusHPE OneView San Manager StatusAvailability3.0.0Status of the resource. Possible values are: OK(0), Disabled(1), Warning(2), Critical(3) , Unknown(4)

Default Monitoring Configurations

HPE OneView has default Global Device Management Policies, Global Templates, Global Monitors and Global Metrics in OpsRamp. You can customize these default monitoring configurations as per your business use cases by cloning respective Global Templates and Global Device Management Policies. We recommend doing this activity before installing the application to avoid noise alerts and data.

  1. Default Global Device Management Policies

    You can find the Device Management Policy for each Native Type at Setup > Resources > Device Management Policies. Search with suggested name in global scope. Each Device Management Policy follows below naming convention:

    {appName nativeType - version}

    Ex: hpe-oneview HPE OneView Resource - 1 (i.e, appName = hpe-oneview, nativeType = HPE OneView Resource, version = 1)

  2. Default Global Templates

    You can find the Global Templates for each Native Type at Setup > Monitoring > Templates. Search with suggested names in global scope. Each template follows below naming convention:

    {appName nativeType 'Template' - version}

    Ex: hpe-oneview HPE OneView Resource Template - 1 (i.e, appName = hpe-oneview, nativeType = HPE OneView Resource, version = 1)

  3. Default Global Monitors

    You can find the Global Monitors for each Native Type at Setup > Monitoring > Monitors. Search with suggested name in global scope. Each Monitors follows below naming convention:

    {monitorKey appName nativeType - version}

    Ex: HPE OneView Resource Monitor hpe-oneview HPE OneView Resource 1 (i.e, monitorKey = HPE OneView Resource Monitor, appName = hpe-oneview, nativeType = HPE OneView Resource, version = 1)