| Redfish Server | redfish_server_APIStatistics | Redfish Server API Statistics | | Usage | 11.2.2 | Returns number of API calls made on each native type for each pole. |
| Manager | redfish_manager_HealthStatus | Redfish Manager Health Status | | Availability | 11.2.2 | Returns the health status of the Manager. Possible states are CRITICAL(0), OK(1), WARNING(2). |
| redfish_manager_State | Redfish Manager State | | Availability | 11.2.2 | Returns the availability state of the Manager. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11). |
| redfish_manager_log_IpmiEventStatistics | Redfish Manager IPMI Log Statistics | count | Usage | 11.2.2 | Returns number of Manager Level IPMI logs are published for each poll |
| Manager Network Interface | redfish_manager_networkInterface_HealthStatus | Redfish Manager Network Interface Health Status | | Availability | 11.2.2 | Returns the health status of the Manager Network Interface. Possible states are CRITICAL(0), OK(1), WARNING(2). |
| redfish_manager_networkInterface_State | Redfish Manager Network Interface State | | Availability | 11.2.2 | Returns the availability state of the Manager Network Interface. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11). |
| redfish_manager_networkInterface_LinkStatus | Redfish Manager Network Interface Link Status | | Availability | 11.2.2 | Returns the link status of the Manager Network Interface. Possible states are LINKDOWN(0), LINKUP(1), NOLINK(2). |
| redfish_manager_networkInterface_SpeedMbps | Redfish Manager Network Interface Speed in Mbps | Mbps | Performance | 11.2.2 | Returns the speed (in Mbps) of the Manager Network Interface. |
| Chassis | redfish_chassis_HealthStatus | Redfish Chassis Health Status | | Availability | 11.2.2 | Returns the health status of the Chassis. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_chassis_State | Redfish Chassis State | | Availability | 11.2.2 | Returns the availability state of the Chassis. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| redfish_chassis_IndicatorLedStatus | Redfish Chassis Indicator Led Status | | Availability | 11.2.2 | Returns the link status of the Manager Network Interface. Possible states are BLINKING(0), LIT(1), OFF(2), UNKNOWN(3) |
| redfish_chassis_PowerState | Redfish Chassis Power State | | Power | 11.2.2 | Returns the Power Status of the Chassis, Possible states are OFF(0), ON(1), POWERINGOFF(2), POWERINGON(3) |
| redfish_chassis_powercontrol_AverageConsumedWatts | Redfish Chassis Power State | | Power | 11.2.2 | Returns average consumed power in watts |
| redfish_chassis_powercontrol_MaxConsumedWatts | Redfish Chassis Power State | | Power | 11.2.2 | Returns the maximum power consumed in watts. |
| redfish_chassis_powercontrol_MinConsumedWatts | Redfish Chassis Power State | | Power | 11.2.2 | Returns the minimum power consumed in watts. |
| redfish_chassis_log_EventStatistics | Redfish Chassis Power State | | Usage | 11.2.2 | Returns event statistics log |
| Compute System | redfish_computeSystem_HealthStatus | Redfish Compute System Health Status | | Availability | 11.2.2 | Returns the health status of the Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_computeSystem_memory_HealthStatus | Redfish Compute System Memory Health Status | | Availability | 11.2.2 | Returns the health status of the Memory of Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2). |
| redfish_server_system_BiosEventStatistics | Redfish Server System BIOS Event Statistics | count | Usage | 11.2.2 | Returns number of BIOS Event Generated for each pole on compute system |
| redfish_computeSystem_State | Redfish Compute System State | | Availability | 11.2.2 | Returns the availability state of the Compute System. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| redfish_computeSystem_HealthRollupStatus | Redfish Compute System Health Rollup Status | | Availability | 11.2.2 | Returns the healthRollup status of the Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_computeSystem_PowerState | Redfish Compute System Power State | | Power | 11.2.2 | Returns the Power Status of the Compute System, Possible states are OFF(0), ON(1), POWERINGOFF(2), POWERINGON(3) |
| redfish_computeSystem_IndicatorLedStatus | Redfish Compute System Indicator Led Status | | Availability | 11.2.2 | Returns the link status of the Compute System. Possible states are BLINKING(0), LIT(1), OFF(2), UNKNOWN(3) |
| GPU | redfish_gpu_HealthStatus | Redfish GPU Health Status | | Availability | 11.2.2 | Returns the health status of the GPU. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_gpu_State | Redfish GPU State | | Availability | 11.2.2 | Returns the availability state of the GPU. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| Processor | redfish_processor_HealthStatus | Redfish Processor Health Status | | Availability | 11.2.2 | Returns the health status of the Compute System Processor. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_processor_State | Redfish Processor State | | Availability | 11.2.2 | Returns the availability state of the Compute System Processor. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| Drive | redfish_drive_HealthStatus | Redfish Drive Health Status | | Availability | 11.2.2 | Returns the health status of the Drive. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_drive_State | Redfish Drive State | | Availability | 11.2.2 | Returns the availability state of the Drive. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| redfish_drive_CapableSpeed | Redfish Drive Capable Speed | Gbps | Performance | 11.2.2 | Returns the Capable Speed (in Gbs) of the Drive. |
| redfish_drive_NegotiatedSpeed | Redfish Drive Negotiated Speed | Gbps | Performance | 11.2.2 | Returns the Negotiated speed (in Gbs) of the Drive |
| redfish_drive_IndicatorStatus | Redfish Drive Indicator Status | | Availability | 11.2.2 | Indicates the status of the Drive. Possible states are FAIL(0), HOTSPARE(1), INACRITICALARRAY(2), INAFAILEDARRAY(3), OK(4), PREDICTIVEFAILUREANALYSIS(5), REBUILD(6) |
| Memory | redfish_memory_HealthStatus | Redfish Memory Health Status | | Availability | 11.2.2 | Returns the health status of the Memory Components. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_memory_State | Redfish Memory State | | Availability | 11.2.2 | Returns the availability state of the Memory Components. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| Network Adapter | redfish_networkAdapter_HealthStatus | Redfish Network Adapter Health Status | | Performance | 11.2.2 | Returns the health status of the Network Adapter. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_networkAdapter_AggregateBandwidth | Redfish Network Adapter Aggregate Bandwidth | Gbps | Performance | 11.2.2 | Redfish Network Adapter Aggregate Bandwidth |
| redfish_networkAdapter_State | Redfish Network Adapter State | | Availability | 11.2.2 | Returns the availability state of the Network Adapter. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| Fan | redfish_fan_HealthStatus | Redfish Fan Health Status | | Availability | 11.2.2 | Returns the health status of the Fan. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_fan_State | Redfish Fan State | | Availability | 11.2.2 | Returns the availability state of the Fan. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| redfish_fan_Reading | Redfish Fan Reading | | Usage | 11.2.2 | Returns the reading value of the Fan. |
| Temperature Sensors | redfish_temperature_HealthStatus | Redfish Temperature Health Status | | Availability | 11.2.2 | Returns the health status of the Temperature. Possible states are CRITICAL(0), OK(1), WARNING(2) |
| redfish_temperature_State | Redfish Temperature State | | Availability | 11.2.2 | Returns the availability state of the Temperature. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11) |
| redfish_temperature_Reading | Redfish Temperature Reading | Celsius | Thermal | 11.2.2 | Returns the reading value (in Celsius) of the Temperature. |
| Firmware | redfish_firmware_IsUpdateable | Redfish Firmware IsUpdateable | | Availability | 11.2.2 | Returns true if firmware is updateable otherwise returns false |
| Software | redfish_software_IsUpdateable | Redfish Software IsUpdateable | | Availability | 11.2.2 | Returns true if software is updateable otherwise returns false |