Resource Hierarchy

  • Redfish Server
    • Manager
      • Manager Network Interface
    • Chassis
      • Compute System
        • Processor
        • GPU
        • Drive
        • Memory
      • NetworkAdapter
      • Power Supply
      • Fan
      • Temperature Sensors
    • Firmware
    • Software

Supported Metrics

Click here to view the supported metrics
Native TypeMetric NameDisplay NameUnitsMetric CategoryApplication VersionDescription
Redfish Serverredfish_server_APIStatisticsRedfish Server API StatisticsUsage11.2.2Returns number of API calls made on each native type for each pole.
Managerredfish_manager_HealthStatusRedfish Manager Health StatusAvailability11.2.2Returns the health status of the Manager. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_manager_StateRedfish Manager StateAvailability11.2.2Returns the availability state of the Manager. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
redfish_manager_log_IpmiEventStatisticsRedfish Manager IPMI Log StatisticscountUsage11.2.2Returns number of Manager Level IPMI logs are published for each poll
Manager Network Interfaceredfish_manager_networkInterface_HealthStatusRedfish Manager Network Interface Health StatusAvailability11.2.2Returns the health status of the Manager Network Interface. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_manager_networkInterface_StateRedfish Manager Network Interface StateAvailability11.2.2Returns the availability state of the Manager Network Interface. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11).
redfish_manager_networkInterface_LinkStatusRedfish Manager Network Interface Link StatusAvailability11.2.2Returns the link status of the Manager Network Interface. Possible states are LINKDOWN(0), LINKUP(1), NOLINK(2).
redfish_manager_networkInterface_SpeedMbpsRedfish Manager Network Interface Speed in MbpsMbpsPerformance11.2.2Returns the speed (in Mbps) of the Manager Network Interface.
Chassisredfish_chassis_HealthStatusRedfish Chassis Health StatusAvailability11.2.2Returns the health status of the Chassis. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_chassis_StateRedfish Chassis StateAvailability11.2.2Returns the availability state of the Chassis. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
redfish_chassis_IndicatorLedStatusRedfish Chassis Indicator Led StatusAvailability11.2.2Returns the link status of the Manager Network Interface. Possible states are BLINKING(0), LIT(1), OFF(2), UNKNOWN(3)
redfish_chassis_PowerStateRedfish Chassis Power StatePower11.2.2Returns the Power Status of the Chassis, Possible states are OFF(0), ON(1), POWERINGOFF(2), POWERINGON(3)
redfish_chassis_powercontrol_AverageConsumedWattsRedfish Chassis Power StatePower11.2.2Returns average consumed power in watts
redfish_chassis_powercontrol_MaxConsumedWattsRedfish Chassis Power StatePower11.2.2Returns the maximum power consumed in watts.
redfish_chassis_powercontrol_MinConsumedWattsRedfish Chassis Power StatePower11.2.2Returns the minimum power consumed in watts.
redfish_chassis_log_EventStatisticsRedfish Chassis Power StateUsage11.2.2Returns event statistics log
Compute Systemredfish_computeSystem_HealthStatusRedfish Compute System Health StatusAvailability11.2.2Returns the health status of the Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_computeSystem_memory_HealthStatusRedfish Compute System Memory Health StatusAvailability11.2.2Returns the health status of the Memory of Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2).
redfish_server_system_BiosEventStatisticsRedfish Server System BIOS Event StatisticscountUsage11.2.2Returns number of BIOS Event Generated for each pole on compute system
redfish_computeSystem_StateRedfish Compute System StateAvailability11.2.2Returns the availability state of the Compute System. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
redfish_computeSystem_HealthRollupStatusRedfish Compute System Health Rollup StatusAvailability11.2.2Returns the healthRollup status of the Compute System. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_computeSystem_PowerStateRedfish Compute System Power StatePower11.2.2Returns the Power Status of the Compute System, Possible states are OFF(0), ON(1), POWERINGOFF(2), POWERINGON(3)
redfish_computeSystem_IndicatorLedStatusRedfish Compute System Indicator Led StatusAvailability11.2.2Returns the link status of the Compute System. Possible states are BLINKING(0), LIT(1), OFF(2), UNKNOWN(3)
GPUredfish_gpu_HealthStatusRedfish GPU Health StatusAvailability11.2.2Returns the health status of the GPU. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_gpu_StateRedfish GPU StateAvailability11.2.2Returns the availability state of the GPU. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
Processorredfish_processor_HealthStatusRedfish Processor Health StatusAvailability11.2.2Returns the health status of the Compute System Processor. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_processor_StateRedfish Processor StateAvailability11.2.2Returns the availability state of the Compute System Processor. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
Driveredfish_drive_HealthStatusRedfish Drive Health StatusAvailability11.2.2Returns the health status of the Drive. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_drive_StateRedfish Drive StateAvailability11.2.2Returns the availability state of the Drive. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
redfish_drive_CapableSpeedRedfish Drive Capable SpeedGbpsPerformance11.2.2Returns the Capable Speed (in Gbs) of the Drive.
redfish_drive_NegotiatedSpeedRedfish Drive Negotiated SpeedGbpsPerformance11.2.2Returns the Negotiated speed (in Gbs) of the Drive
redfish_drive_IndicatorStatusRedfish Drive Indicator StatusAvailability11.2.2Indicates the status of the Drive. Possible states are FAIL(0), HOTSPARE(1), INACRITICALARRAY(2), INAFAILEDARRAY(3), OK(4), PREDICTIVEFAILUREANALYSIS(5), REBUILD(6)
Memoryredfish_memory_HealthStatusRedfish Memory Health StatusAvailability11.2.2Returns the health status of the Memory Components. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_memory_StateRedfish Memory StateAvailability11.2.2Returns the availability state of the Memory Components. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
Network Adapterredfish_networkAdapter_HealthStatusRedfish Network Adapter Health StatusPerformance11.2.2Returns the health status of the Network Adapter. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_networkAdapter_AggregateBandwidthRedfish Network Adapter Aggregate BandwidthGbpsPerformance11.2.2Redfish Network Adapter Aggregate Bandwidth
redfish_networkAdapter_StateRedfish Network Adapter StateAvailability11.2.2Returns the availability state of the Network Adapter. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
Fanredfish_fan_HealthStatusRedfish Fan Health StatusAvailability11.2.2Returns the health status of the Fan. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_fan_StateRedfish Fan StateAvailability11.2.2Returns the availability state of the Fan. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
redfish_fan_ReadingRedfish Fan ReadingUsage11.2.2Returns the reading value of the Fan.
Temperature Sensorsredfish_temperature_HealthStatusRedfish Temperature Health StatusAvailability11.2.2Returns the health status of the Temperature. Possible states are CRITICAL(0), OK(1), WARNING(2)
redfish_temperature_StateRedfish Temperature StateAvailability11.2.2Returns the availability state of the Temperature. Possible states are ABSENT(0), DEFERRING(1), DISABLED(2), ENABLED(3), INTEST(4), QUALIFIED(5), QUIESCED(6), STANDBYOFFLINE(7), STANDBYSPARE(8), STARTING(9), UNAVAILABLEOFFLINE(10), UPDATING(11)
redfish_temperature_ReadingRedfish Temperature ReadingCelsiusThermal11.2.2Returns the reading value (in Celsius) of the Temperature.
Firmwareredfish_firmware_IsUpdateableRedfish Firmware IsUpdateableAvailability11.2.2Returns true if firmware is updateable otherwise returns false
Softwareredfish_software_IsUpdateableRedfish Software IsUpdateableAvailability11.2.2Returns true if software is updateable otherwise returns false